Plasma cutter

To investigate was:

I tried the old Parkside torch again, with brand new consumables, and it is very obviously worse than the P80 torch. The P80 torch pretty reliably cuts through the 5mm plate at 300 mm/min but the Parkside is nowhere near.

So definitely the P80 torch is an improvement.

The Parkside torch nozzles are ~1.4mm btw, but unsure how comparable the orifice size is between different torch designs.

I tried spraying air from the compressor onto a paper towel for 30 seconds to see if there is any moisture visible on the paper towel and there is not, it looks almost totally clean, just damaged slightly from having air blasted at it for 30 seconds.

So the most pressing issue is why are we wearing out nozzles so fast?

Wearing out a nozzle really fast but an electrode no faster than normal is apparently evidence of "double-arcing", where the arc jumps from the electrode to the nozzle and then from the nozzle to the workpiece, instead of being confined by the air flow.

So that could mean not enough airflow?

This paper https://cdn.intechopen.com/pdfs/20904/InTech-On_the_double_arcing_phenomenon_in_a_cutting_arc_torch.pdf identifies "too large arc current, too small gas mass flow, or a nozzle with a too small bore diameter or with a too large length" as possible reasons for double-arcing.

And:

double-arcing is very undesirable; since the arc roots on the nozzle wall (especially that corresponding to the arc originated from the cathode) usually destroy the nozzle almost instantaneously

Double-arcing could also explain why I've seen the jet flickering around, it could sometimes be coming out straight and sometimes coming off one side of the nozzle.

I reckon this is what is happening.

I am tempted to rebuild the pump on the compressor just in case it has any damaged gaskets or something that are limiting how hard it can pump.

I can feel air blowing out of the side of the cylinder or head while it's pumping but I can't tell where from. I took it apart, cleaned up mating surfaces, and reassembled them with fresh gasket goo in place of perished paper gaskets, but still blows out the side just the same as before.

OK, update: double-arcing is not actually possible here. Double-arcing is where the arc jumps from the electrode to the nozzle and then from the nozzle to the workpiece. But since my nozzle is permanently wired to the same electrode as the workpiece, there would be no voltage left to jump to the workpiece if this were happening.

Is that actually possibly what's happening sometimes though? Just because the jet is coming out doesn't mean the arc isn't attaching to the nozzle does it? Otherwise the pilot arc wouldn't be able to produce a jet and we know it does.

Also possible that there is one arc to the workpiece and one to the nozzle? Causing less current going into the workpiece and excess nozzle wear.

It would be interesting to measure the current on the pilot arc return wire during cutting.

In particular may want to measure continuously and plot over time, because even intermittent pilot arc current would be a problem.

So my earlier test cutting with pilot arc disconnected was maybe pointing in the right direction, except in that case the nozzle was already damaged so proved nothing.

Although my other earlier test that showed 30A on the work return cable does suggest that there's not significant current going through the pilot arc return. That was with the original torch though.

Maybe the P80 actually does need something to switch off the pilot arc after it transfers to the work piece?

Maybe I could rig up a sort of relay so that current in the work-return cable disconnects the pilot arc return?

Or add a current-limiting resistor? Probably start with a resistor because breaking contacts carrying 100v at 30A is not that trivial?

What kind of resistor do I want? I think a resistor that can genuinely handle 100v at 30A is more expensive than the plasma cutter was.

And beyond that, let's say I fit a resistor - how do I tell if it's working? Probably want a good way to continuously measure current in the pilot arc return wire. Apparently can cause nozzle damage even if current-sharing only lasts a few milliseconds.

Thread where someone adds both a current-limiting resistor and a relay: https://www.mig-welding.co.uk/forum/threads/cut-50-how-to-add-a-pilot-arc.144843/

And YouTube video: https://www.youtube.com/watch?v=XuRwu0ZYzdg

A DC current-sensing switch is an off-the-shelf part you can just buy.